SERVICE

HVAC — heating, ventilation, air conditioning

Heating and cooling loads, equipment selection, ductwork and pipework.

We calculate loads on real operating profiles and select equipment that performs at part load, not only at peak.

MEP ENGINEERING
01 — SCOPE
Scope

Heating and cooling load calculations to EN 12831 and ASHRAE methods

Heating scheme: heat source, substation, circuits, balancing

Ventilation: air change by room function, heat recovery, smoke extract

Air conditioning: VRF, chiller–fan coil or split, with comparison and rationale

Kitchen and sanitary extract systems

Noise and vibration control: attenuators, anti-vibration mounts, routing

Deliverables

Design report with load calculations

Plans with ductwork and pipework

Plant room and substation details

Equipment schedule with parameters

Bill of quantities for procurement

Balancing schedule for commissioning

Building types

Hotels

Residential

Offices

Restaurants

Clinics

Standards

EN 12831

EN 16798-1

ASHRAE 62.1

ASHRAE 90.1

Typical problems we solve
01

Not enough ceiling void for ductwork

We switch to flat sections, split the load across two systems or change the scheme. The decision is made in the model, not on site.

02

Safety margins inflate the budget

We recalculate on actual occupancy and operating hours. Equipment often drops one size.

03

Cold in winter, noisy in summer

We check balancing and supply air velocity; the problem is usually regulation, not capacity.

FAQ

VRF or chiller?

It depends on area, zoning and servicing. Below 3,000 m² usually VRF; on larger buildings chiller–fan coil. We provide a cost-of-ownership comparison.

Is heat recovery worth it?

Where ventilation runs continuously, yes — it returns through the heating bill.

Can you audit an existing system?

Yes, we measure flows and temperatures and issue a list of what needs to change.

02 — PROCESS

Process

01

Survey and brief

We measure what exists: available capacity, pipe sizes, slab-to-ceiling heights, routing of services. We write the brief, the client approves it.

02

Concept and load calculations

Heating and cooling loads to EN 12831, electrical balance, water demand. This is where the kW and m³/h you will request from utilities are fixed.

03

Schematic design

Equipment layout, plant room areas, main shafts and routes. Agreed with the architect before the façade and ceilings close.

04

Detailed design

Plans, schematics, details, specifications and bills of quantities. Clashes are resolved in the model — pipe and duct meet on screen, not on site.

05

Technical conditions and approvals

Applications to utility companies, fire section review, closing of comments. We keep a log of what was submitted and when.

06

Tender and suppliers

We issue a procurement sheet with technical parameters and compare offers on service and spare-part availability, not price alone.

07

Site supervision

Scheduled visits, hidden-works records, change tracking. An installation error is corrected while the ceiling is still open.

08

Commissioning and handover

Air and water balancing against design, interlock testing, as-built documentation and an operating manual for the facility team.